P-30E Self-Contained Regenerative Respirator

P 30E web

The P-30E respirator is an upgraded model of the P-30 respirator with 4 hours operation time and is used as a basic device for mine rescue, firefighting and for operations on industrial facilities where there is a IDLH atmosphere where the length of operations is likely to be more than 2 hours.

The P-30E has two alarms:

  • closed cylinder valve (empty cylinder) alarm;
  • low cylinder pressure alarm.

This respirator has a lighter composite cylinder with a 2 liter capacity. It can be equipped either with a mouthpiece or a full face mask.

The P-30E has an improved ergonomic harness. The apparatus is adjusted with the help of the UKP-5 instrument and we recommend using a KD-8 booster compressor to refill small- size cylinders.

We have taken into account previous experiences of P-30’s respirator operation, collected information from its users from all over the world and introduced design and technical solutions to improve the P-30E model. Specifications and breathing conditions are fully compliant with EN 145 European Standard requirements.

No electronics is used in P-30E.

 

 

Operation time, hours 4
Weight w/o facemask, kg  
with ice 11.5
without ice 10.7
Oxygen reserve, l 400
Working pressure, MPa 20
Oxygen supply to the respirator system, l/min:  
Constant** 1.5**
Demand valve, not less 70
Emergency valve 60 to 150
Dimensions, mm: 450x375x165

* — for further information about spare parts, contact the manufacture, dealer or service center.